Current availability for non-stock parts is "Usually ships in 7-10 business days". This manual describes how to use UT55A/UT52A functions other than UT55A/UT52A's communication function and ladder sequence function . This instrument is intended for permanent installation, for indoor use only, in an electrical panel which encloses the rear housing, exposed terminals and wiring on the back. SSc allows the scaling of the analog input to set the minimum displayed/measured value. Products and components that are subject to wear due to conditions. user must refer to the Engineering manual for special instructions. The UT32A/MDL supports 920 MHz band wireless communication. This manual is intended for the following personnel: - Engineers responsible for installation, wiring, and maintenance of, - Personnel responsible for normal daily operation of the, Calls attention to actions or conditions that could cause serious or, fatal injury to the user or damage to the instrument, and indicates, precautions that should be taken to prevent such occurrences. Push button for more than 3 seconds, the instrument will come back to the standard display. The TC series of temperature controllers is perfect for controlling the heating temperature of sealing parts and the temperature of sealing rolls (pre-heating) in a variety of different wrapping machinery. - Modification of the product is strictly prohibited. For measurements performed in the building instal-, For measurements performed at the source of the, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. when you re-congure an instrument previously used for other works or from other people or when you have made too many errors during conguration and you decided to re-congure the instrument, it is possible to restore the factory conguration. TC10s compact design allows for a broad range of applications/uses while maintaining a high level of accuracy. Category: Controller. the protection provided by this instrument may be impaired. I want to use the detailed parameter setting method of TC10, but what number is the password? We assume no liability for safety, or responsibility for, the product's quality, performance or functionality should users. Also, YOKOGAWA Electric Corporation assumes no liability for the customer's, failure to comply with these requirements. D + D - D + D - D + D - D + D - RS-485 5 6 The TC10 communication setting criteria are as follows. All information about the controller use can be found in the Engineering Manual: - IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN and General Specification: GS 05C01E81-01EN. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O. Yokogawa Electric Corporation - TC10 - ENGINEERING MANUAL - PAG. Use of the, instrument in a manner not prescribed herein may compromise, the product's functions and the protection features inherent in, the device. The ambient temperature is in accordance with the operative, 6. all phases of operation, service and repair of this instrument. desired, the optional gasket must be mounted. -For supply connections use No. Configuration Page For: TC10 TEMPERATURE CONTROLLER TC10 TC10; Configuration Page For: TC10 Limit Controller TC10-L TC10-L; 21; Model: LL50A Parameter Setting Tool and PLC Ladder Building Tool I want to use it as a display. The following general safety precautions must be observed during. The TC10 supports easy configuration with codes for quick start-up. The 3-year warranty extends 36 months after shipment from our factory. Can you issue a TC10 calibration certificate? 0/4 to 20 mA input wiring for passive transmitter using the auxiliary pws. Yes, by changing the DP setting from 0 to 1. View online (2 pages) or download PDF (1 MB) YOKOGAWA TC10 User manual TC10 measuring, testing & control PDF manual download and more YOKOGAWA online manuals Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. ]inP Group - Main and auxiliary input conguration. What settings should I use to output PV transmission from ananalog output terminal on TC10? Cold junction accuracy: 0.04C/C after a warm-up of 20 minutes. requirements of the area in which the instrument is being installed. In the following pages we will describe all the parameters of the instrument. Do not run input wires together with power cables. The UT35A and UT32A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - Digital Input (DI2) connecting a free of. 4. 1, This instrument is intended for permanent installation, for, indoor use only, in an electrical panel which encloses the. When the maximum front protection (IP65) is. connected to the low-voltage installation. The instrument behaviour and its performance are governed by the value of the stored parameters. terminal 1 and 2 to transmitter signal output. all phases of operation, service and repair of this instrument. The default data are those typical values loaded in the instrument prior to ship it from factory. - Install the power cable keeping a distance of more than 1 cm from, - The power cable is required to meet the IEC standards concerned or the. Download Instructions manual of digitalview ALR-1400 Controller for Free or View it Online on All-Guides.com. What is the I/O response time of the TC10? Internal auxiliary PWS: 12 VDC (10%), 20 mA max.. 0/4 to 20 mA input wiring for passive transmitter using an external pws, 0/4 to 20 mA input wiring for active transmitter. Worked Time counter is continuously increased when, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. This action allows to put the instrument in a dened condition (the same it was at the rst power ON). 5.5 KEYBOARD FUNCTIONS DURING PARAMETER CHANGING. - For control relay output, alarm relay output, and power terminal, -N o C o o o D o F Temperature Controller, The TC10-N can be easily configured by the "Code Configuration" method for the most common requirements, just entering two 4-digit. Note: For TC and RTD inputs the decimal figure must be 0 or 1 only. facilities, aviation facilities, and medical equipment. voltage contact between terminals 4 and 16; - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. Assign OP4 to the control output operation. The EU Declaration of Conformity and the manual of the controller. 2. There's no SG terminal for wiring RS485 communication on the TC1. Wattmeter Instantaneous power is continuously computed, as multiplication of the Load Voltage, Load Current parameter. Can I hide the SP display? Installation altitude: less than 2000 m; The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. The TC series of temperature controllers is perfect for controlling the heating temperature of sealing parts and the temperature of sealing rolls (pre-heating) in a variety of different wrapping machinery. TC10 TEMPERATURE CONTROLLER Engineering Manual Code: IM 05C01E81-02EN Third edition: Feb. 2018 Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns 1. TC10 does not come with a terminal cover. Do not run logic input wiring together with power cables; The instrument needs 150 ms to recognize a contact status variation; To avoid electrical shocks, connect power line at last. Sometime, e.g. TC10 is a panel mounting, Class II instrument. The following symbol is, This manual is an essential part of the product; keep it in a safe place for. The ambient temperature is in accordance with the operative, 6. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. 3 2.3 OUTPUTS Safety notes: - To avoid electrical shocks, connect power line at last. All information about. The. : input type, Control strategy, alarms, etc.). The output (OUT) display lamp is lit. (100 to 240 VAC), Insulation voltage: 2300 V rms according to EN 61010-1, Front protection: IP 65 (when the optional panel gasket is mounted), Accessories: Mounting bracket, Quick Guide, Operative Modes: Auto / Manual / Stand-by (force control output to zero), Serial Communication (optional): RS-485 MODBUS, PID control with single or double action with overshoot control (Fuzzy overshoot control), ON/OFF, ON/OFF Neutral Zone, Auto-tuning, and Self-tuning. Note: The group selection is cyclic as well as the selection of the parameters in a group. The instrument have one complete parameter set. IM 05C01E81-01EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, EU Declaration of conformity and Manual retrieval, TC10 is a panel mounting, Class II instrument. Search the full list . Input impedance: > 1 MW for mV Input 500 kW for Volt Input. Looking for more information on our people, technology and solutions? {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Special Solutions of OpreX Transformation, Visual MESA Supply Chain Scheduling (VM-SCS), Visual MESA Production Accounting (VM-PA), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), Digital Plant Operation Intelligence (DPI) Quality Stabilization System, OpreX Data Model Broker / Design Data Validation, OpreX Customer Service Management Software, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Single-Cell Analysis Solution Single Cellome, Distributed Temperature Sensor - Fire Detection/Fire Prevention -, Industry and Interface Libraries (Applications and Interfaces), Advanced Control Bioreactor System BR1000, ALH for FlowCam: Automated Liquid Handling, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, Support InformationNew Legislative Framework (NLF) Conforming Products, Temperature Control for Seal-heating Parts in Wrapping Machinery. Select a mounting location having the following characteristics: 2. Yokogawa TC10 Temperature Controller Starting at $203.00 Select Options and Add to Cart View Company Reviews Manufactured By Yokogawa Includes FREE Ground Shipping on orders of $1,000 or more FREE Lifetime Tech Support Availability Usually ships in 2-3 weeks Product Manual Product Specs Overview Description Documents Accessories Features With thermocouple K input, can I display digits after the decimal point for the temperature? A ladder sequence function is included as standard. that no power is being supplied to a cable to be connected. High Quality SDA25x30 Pneumatic SDA25-30mm Double Acting Compact AIR Cylinder. At this point you can set the operator. TC10. When a shielded cable is used, it should be connected at one point only. Digital indicating controllers (82 pages), Digital indicating controller (236 pages), Digital indicating controllers (13 pages), Digital indicating controller 16 AWG or larger wires rated for at last 75C. The conguration parameters are collected in various groups. Case: Plastic, self-extinguishing degree: V-0 according to UL 94, Front protection: IP 65 (when the optional panel gasket is mounted) for indoor locations according to EN 60070-1, Terminals protection: IP 20 according to EN 60070-1, Terminal block: 16 screw terminals for cables of 0.25 to 2.5 mm2 (AWG22 to AWG14) with connection diagram, tightening torque 0.5 Nm, Dimensions: 48 x 48, depth 62 mm (1.89 x 1.89 x 2.87 in. 1.Do not run input wires together with power cables. 2.56 in min. Model: TC10 - Quick Guide . View online (36 pages) or download PDF (3 MB) YOKOGAWA TC10 User manual TC10 PDF manual download and more YOKOGAWA online manuals parameter and than you can use the instrument. For supply connections use No. Available: When a linear input is selected by [1] SenS. Product Manual Product Specs Overview Description Documents In Stock 2. suit your application (e.g. We assume no liability for safety, or responsibility for, the product's quality, performance or functionality should users. Pay attention to the line resistance; a high line resistance, Digital indicating controllers (476 pages), Program temperature controller (37 pages), Temperature measurement module (44 pages), Manual will be automatically added to "My Manuals", Keyboard Functions During Parameter Changing, Factory Reset - Default Parameters Loading Procedure, How to See but Not Modify "Limited Access Parameters", Keyboard Function When the Instrument Is in Auto Mode, Temperature Controller YOKOGAWA TC10 Quick Manual, Temperature Controller Yokogawa TC10 Quick Manual, Temperature Controller YOKOGAWA TC User Manual, Temperature Controller YOKOGAWA UT55A User Manual, Temperature Controller YOKOGAWA UP150 User Manual, Temperature Controller YOKOGAWA XS550 User Manual, Temperature Controller YOKOGAWA UT130 Technical Information, Temperature Controller YOKOGAWA UT150 User Manual, Temperature Controller YOKOGAWA UT100 Series User Manual. Can I turn off the "C" display with input other than temperature on TC10? values and the controller output instantaneous value. any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and ". The TC10 supports easy configuration with codes for quick start-up. With thermocouple K input, can I display digits after the decimal point for the temperature? A reinforced isolation must be assured by the external solid state relays. : 500W. TEMPERATURE . The output relay is always de-energized (opened) at poweron,even if PV does not exceed SP(A). Features 3 Dynamic Colors Led Display Compact size: 48 x 48 mm (1/16 DIN), depth 48 mm 1. 5.6 FACTORY RESET - DEFAULT PARAMETERS LOADING PROCEDURE. Select a mounting location having the following characteristics: 2.There is minimum vibrations and no impact; 4.There are no water or other uids (i.e. Main Features Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals) 3 Dynamic Colors Led Display The Yokogawa TC10-L limit controller is an FM-approved limit controller that can be configured either as a high limit or as a low limit controller by a user. Other part numbers are available to order but are not currently in stock. The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. When installing the TC10, what is the depth in millimeters from the surface of the panel? All information about the controller use can be found in the Engineering Manual: IM 05C01E81-12EN and the Communication Manual: IM 05C01E81-13EN and General Specification: GS 05C01E81-11EN.